DRC-12V30W1AZ

Output Voltage: 12V

Output Power: 25W

Output Current: 2.1A

Input Voltage Range: 90-264Vac

Dimensions (H x W x D): 91 x 53 x 55.6 mm

Unit Weight: 0.14 kg (0.31 lb)

Highlights & Features

  • Class II, Double Isolation (No Earth connection is required)
  • Universal AC input voltage range and full power up to 55°C
  • Power will not de-rate for the entire input voltage range
  • Efficiency > 85.0% @ 115Vac & 230Vac
  • Can be installed in compact cabinets
  • NEC Class 2 and Limited Power Source (LPS) approvals
  • Conforms to harmonic current IEC/EN 61000-3-2, Class A
  • Safety approval according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1 and UL508

 

Output Current: 2.1A

Output Voltage: 12V

Output Voltage Adjustment Range: 11.5-14.5Vdc

Output Power: 25W

Line Regulation: < 0.5% (@ 90-264Vac input, 100% load)

Load Regulation: < 1.0% (@ 90-264Vac input, 0-100% load)

PARD: < 100mVpp

Start-up Time: < 2,000ms @ nominal input (100% load)

Hold-up Time: > 25ms @ 115Vac, > 60ms @ 230Vac (100% load)

Dynamic Response (Overshoot & Undershoot O/P Voltage): ± 5% @ 90-264Vac input, 10-100% load (Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz to 100Hz)

Start-up with Capacitive Loads: 3,000µF Max

Rise Time: < 70ms @ nominal input (100% load)

 

Nominal Input Voltage: 100-240Vac

Input Voltage Range: 90-264Vac

Nominal Input Frequency: 50-60Hz

Input Frequency Range: 47-63Hz

DC Input Voltage Range: 125-375Vdc

Input Current: < 0.80A @ 115Vac, < 0.60A @ 230Vac

Efficiency at 100% load: > 85.0% @ 115Vac & 230Vac

Inrush Current: < 25A @ 115Vac, < 50A @ 230Vac

Leakage Current: < 0.25mA @ 240Vac

Power Dissipation: 0% load: < 0.3W @ 115Vac & 230Vac, 100% load: < 4.4W @ 115Vac & 230Vac

 

Case Chassis / Cover: Plastic

Indicator: Green LED (DC OK)

Cooling System: Convection

Input Terminal: 2 Pins (Rated 300V/25A)

Output Terminal: 4 Pins (Rated 300V/25A)

Noise Sound Pressure Level (SPL): < 25dBA

Mounting Rail: Standard TS35 DIN Rail in accordance with EN 60715

Wire: Input / Output: AWG 22-12

Unit Weight: 0.14 kg (0.31 lb)

 

Dimensions: 91 x 53 x 55.6 mm

Vibration (Operating) : IEC 60068-2-6, Sine Wave: 10-500Hz @ 19.6m/S² (2G peak);
10 min per cycle, 60 min for all X, Y, Z directions

Shock Test (Operating): IEC 60068-2-27, Half Sine Wave: 4G for a duration of 22ms,
3 shocks for each 3 directions, 9 times in total

Operating Temperature: -25°C to +71°C

Storage Temperature: -25°C to +85°C

Power De-rating: > 55°C de-rate power by 2.5% / °C

Operating Humidity: 5 to 95% RH (Non-Condensing)

Operating Altitude: 0 to 2,000 Meters (6,560 ft.)

Pollution Degree: 2

Over Voltage Category: II

 

Overvoltage: < 17.4V, SELV Output, Latch Mode

Overload / Overcurrent: > 130% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)

Over Temperature: > 75°C Surrounding Air Temperature @ 100% load, Latch Mode

Short Circuit: Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)

Degree of Protection: IP20

Protection Against Shock: Class II (No Primary Earth connection is required)

 

Electrical Safety: TUV Bauart: EN 60950-1, EN 62368-1
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881)
CB scheme: IEC 60950-1, IEC 62368-1, Limited Power Source (LPS)

CE: In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU

Galvanic Isolation: Input to Output: 3.0KVac

Industrial Control Equipment: UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E338991)

Safety Entry Low Voltage: SELV (EN 60950)

UKCA: In conformance with 2016 No. 1101. The Electrical Equipment (Safety) Regulations 2016 and 2016 No. 1091 The Electromagnetic Compatibility Regulations 2016

 

Γιατί να συνεργαστείτε με την PALS

Ποικιλία
Μεγάλη ποικιλία ειδών, ανταγωνιστικές τιμές και προδιαγραφές καλής ποιότητας
Δωρεάν Μεταφορικά
Δωρεάν αποστολή για παραγγελίες άνω των 50€ (εντός Αθηνών)
Άμεση Υποστήριξη
Επικοινωνήστε μαζί μας για να σας βοηθήσουμε