UPS ON LINE 1KVA MUST EH5200 series - HC1000VA
Μπαταρίες: 3 x 12V-7Ah.
Οθόνη LCD, πρίζες IEC, Θύρα USB.
Διαστάσεις: 35x14,5x22 εκ.
Βάρος: 12Kg.
Model |
H1K |
|
H2K |
H3K |
||
Capacity |
||||||
VA/W |
1KVA/0.9KW |
2KVA/1.8KW |
3KVA/2.7KW |
|||
Input |
||||||
Voltage Range |
Full Load:160±50%VAC~300±50%VAC;Half Load:110±50%VAC~300±50%VAC |
|||||
Frequency Range |
40-70Hz |
|||||
Phase |
Single phase two wire+ground wire |
|||||
Distortion |
<5% |
|||||
Power factor |
0.99 |
|||||
Generator input |
support |
|||||
Output |
||||||
Voltage |
220 (1±1%)VAC |
|||||
Frequency (same frequency mode) |
47~53Hz/57~63Hz |
|||||
Power Factor |
0.9 |
|||||
Frequency (battery mode) |
50±0.25Hz or 60±0.25Hz |
|||||
Crest ratio |
03:01 |
|||||
Harmonic distortion |
≤3%THD (Linear load) |
|||||
≤6%THD (Nonlinear load) |
||||||
Output waveform |
Pure Sine Wave |
|||||
Socket |
Universal socket *2 |
Universal socket *4 |
Universal socket *3+Terminal block |
|||
Over Load |
100%-110%: warning sound; |
|||||
Efficiency |
||||||
Charging Mode |
85% |
88% |
||||
Battery Mode |
83% |
85% |
||||
Battery |
||||||
Battery Type |
12V/7AH |
/ |
12V/7AH |
/ |
12V/7AH |
/ |
Battery Number |
3 |
6 |
8 |
|||
Equipment time (full load) |
>5mins |
>5mins |
>5mins |
|||
Charging Time(90%) |
8h |
8h |
8h |
|||
Charge battery (max) |
1.0A |
1.0A |
4.0 |
1.0A |
||
Rated charging voltage |
41.0±1%VDC |
82.1±1%VDC |
109.4±1%VDC |
|||
Temperature detection |
support |
|||||
Conversion time |
||||||
Utility to Battery |
0ms |
|||||
Inverter to bypass |
4ms |
|||||
Utility Priority Mode |
support |
|||||
Warning Alarm |
||||||
Battery Mode |
Alarm every 4 seconds |
|||||
Low Power |
Alarm every one second |
|||||
Over Load |
Alarm 2 every second |
|||||
Fault |
continuous alarm |
|||||
Shape |
||||||
Dimension (D*W*H) mm |
350*145*220 |
425*190*320 |
||||
Net weight(Kg) |
12 |
24 |
11 |
29 |
||
Connector |
||||||
Micro RS-232 |
Windows,Linux,Sun Solaris,IBM Aix,Compaq True64,SGIRIX,FreeBSD,HP-UX and MAC |
|||||
USB(Optional) |
Windows & MAC |
|||||
Rabbet(Optional) |
SNMP/AS400 Relay Card/Rs485 |
|||||
EPO(Optional) |
Support emergency shutdown |
Features
- With double conversion online design, zero output transfer time;
- Adopt DSP digital control, excellent performance indicators, more steady and reliable;
- Adopt active power factor correction technology (PFC), the input power factor is 1, can reduced the pollution to the grid, To energy saving and reducing system investment cost;
- Ultra-wide input voltage range , input voltages available 115V instead of turn to battery power;
- With LCD+LED real-time display, UPS operating available for Detection;
- With self- detection function, can detect hidden faults of UPS;
- Cold start by battery without grid Input;
- Input frequency range 40~70Hz, support various fuel generators;
- With AC input over voltage, low voltage protection, output overload protection, short circuit protection, temperature protection, battery low voltage warning protection and battery overcharge protection;
- Output power factor 0.9, stronger load capacity, efficiency reach 90%, reduce loss of UPS;
- With input neutral and live line detection function, avoid the reverse connection of UPS utility input;
- When utility cut-off, the UPS discharge battery in the battery mode; when the utility power is recovery ,UPS turn on automatically, and charge battery at the same time, as unattended function;
- Standard RS232 communication outlet ,connect UPS and computer to realize multifunctional and multi-purpose monitoring and management operations, available SNMP card (optional) to UPS remote monitoring function.
Application
Widely used in small and medium-sized enterprise data center, small financial system network, industrial automation control system, LAN server, CBS server, Shopping center cashier, bank securities, tax, communications, postal, transportation, Power, medical, industrial control, petrochemical.